Page 1 - Operating Instructions

WIKA Alexander Wiegand GmbH & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Phone (+49) 93 72/132-0 Fax (+49) 93 72/132-406 E-Mai

Page 2 - Caution

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 10 - 3. Mounting to control panel 3.1 Site selection This i

Page 3

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 11 - 3.3 Panel cutout • CS4H Lateral close moun

Page 4 - 05/2006 - 4

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 12 - 3.5 Mounting (both CS4H and CS4L) Warning As the cas

Page 5 - 05/2006 - 5

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 13 - 4. Wiring connection Warning Turn the power supply to

Page 6 - 1. Model informations

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 14 - Caution • The terminal blocks of the CS4H and CS4L are

Page 7 - 05/2006 - 7

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 15 - [Heater burnout alarm output] (1) This alarm is not av

Page 8 - 05/2006 - 8

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 16 - 5. Setup For the thermocouple and RTD inputs, the sensor

Page 9 - Notice

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 17 - 5.1 Setup flow chart

Page 10 - 3. Mounting to control panel

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 18 - ▲+▼+ MODE (

Page 11 - 05/2006 - 11

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 19 - 5.2 Main setting mode If the MODE key is pressed, main s

Page 12 - Warning

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 2 - Preface Thank you for the purchase of our microcomputer

Page 13

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 20 - Integral time setting [] • Sets the integral time. Sett

Page 14 - Caution

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 21 - HB (Heater burnout alarm) setting [ and X.X are indica

Page 15 - Power source

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 22 - 5.4 Auxiliary function setting mode 1 In the PV/SV dis

Page 16 - 5. Setup

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 23 - Data transfer rate selection [] • Selects the data tran

Page 17 - 5.1 Setup flow chart

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 24 - 5.5 Auxiliary function setting mode 2 In the PV/SV dis

Page 18 - ▲+▼+ MODE (Approx. 3s)

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 25 - Decimal point place selection [] • Selects the decimal

Page 19 - ▲ or ▼key

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 26 - Overlap band/Dead band setting [] • Sets Overlap band/D

Page 20 - 05/2006 - 20

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 27 - A1 action delayed timer setting [] • Sets the action de

Page 21 - 05/2006 - 21

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 28 - [Sensor correction function] This corrects the inpu

Page 22 - ▲ or ▼ key

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 29 - 5.6 Control output OFF function Control output OFF fu

Page 23 - 05/2006 - 23

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 3 - 1. Installation precautions Caution This instrument is i

Page 24

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 30 - 6. Running After the controller has been mounted to the

Page 25 - 05/2006 - 25

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 31 - 7. Action explanation 7.1 OUT1 action

Page 26 - 05/2006 - 26

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 32 - 7.3 OUT1 ON/OFF action Heating (re

Page 27 - 05/2006 - 27

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 33 - 7.4 OUT2 (Heating/Cooling control) action (option)

Page 28 - 05/2006 - 28

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 34 - When setting Dead band

Page 29

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 35 - When setting Overlap band with Relay contact output.

Page 30 - 6. Running

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 36 - 7.5 A1 and A2 actions

Page 31 - 7. Action explanation

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 37 - For A2 output, terminals 12 and 13 are used. A1

Page 32 - 05/2006 - 32

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 38 - 8.2 PID auto-tuning of this controller In order to dec

Page 33 - 05/2006 - 33

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 39 - 8.3 Auto-reset (offset correction) Auto-reset is perform

Page 34 - 05/2006 - 34

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 4 - List of contents 1. Model informations 1.1 Model name ··

Page 35 - - 35

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 40 - 9. Specifications 9.1 Standard specifications Mounting m

Page 36 - 7.5 A1 and A2 actions

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 41 - Accuracy (Setting, indication) Thermocouple : Within ±

Page 37 - : Standby functions

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 42 - Supply voltage : 100 ... 240 V AC 50/60Hz or 24 V AC/D

Page 38 - 05/2006 - 38

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 43 - Attached functions [Sensor correction function] [Settin

Page 39 - 05/2006 - 39

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 44 - [Burnout] When the thermocouple or RTD input is burnt ou

Page 40 - 05/2006 - 40

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 45 - 9.2 Optional specifications Alarm output 2 (A2) process

Page 41 - 05/2006 - 41

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 46 - Heating/Cooling control [option codes: DR2, DS2, DA2] Wh

Page 42 - 05/2006 - 42

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 47 - 10. Troubleshooting If any malfunctions occur, refe

Page 43 - 05/2006 - 43

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 48 - Problem Presumed cause and solution

Page 44 - Thermocouple input type)

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 49 - 10.3 Control Problem Presumed cause

Page 45 - 05/2006 - 45

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 5 - A2 action selection ·····································

Page 46 - 05/2006 - 46

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 50 - [Auxiliary function setting mode 1] Character Setting it

Page 47 - Warning

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 6 - 1. Model informations 1.1 Model name and order code

Page 48 - ▲ or ▼- key is

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 7 - 1.2 Rated input Input type Input range Resolution –200

Page 49 - 05/2006 - 49

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 8 - 2. Name and functions of the sections (Fig.

Page 50 - - 50

Operating Instructions Temperature Indicating Controller CS4H / CS4L V1.1 • 05/2006 - 9 - Keys: (12) ▲: Increase key Increases numeric value of