6 Commissioning, operation
WIKA Operating Instruction, Model Pascal 100 and Pascal 100/IS 85
GB
6.10.4 Example 4 Calibration of Thermocouples
The calibration of thermocouples is similar to that of RTDs, i.e. by comparison, except for the
choice of the type of reference thermocouple to be used accordingly to the types of thermocouples
to be calibrated.
You must also select the cold junction compensation if the internal, external or assigning a
compensation value.
The figure below shows the connection of the calibrator:
Figure 109 Thermocouple calibration example
Reference TC
DUT TC
Thermostat (Liquid Bath Dry Block)
Comparison method