WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30
63911 Klingenberg • Germany
Tel. (+49) 9372/132-0
Fax (+49) 9372/132-406
www.wika.de
31014275.01 08/2011 GB/D
Contents
1. Safety
2. Description
3. Specications and intended use
4. Commissioning
5. Maintenance and cleaning
Appendix 1: Declaration of conformity for
models 111.xx, 113.53, 213.40 and 213.53
Installation with
open-ended
spanner
Operating
instructions
1. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate
pressure gauge has been selected in terms of measuring range, design and
specic measuring conditions.
Check the compatibility with the medium of the materials subjected to pressure!
In order to guarantee the measuring accuracy and long-term stability specied, the
corresponding load limits must be observed.
Non-observance can result in serious injury and/or damage to the equipment.
Only qualied persons authorised by the plant manager are permitted to install, maintain
and service the pressure gauges.
2. Description
Nominal sizes
Model 111.10: NS 40, 50, 63, 80, 100, 160 Model 113.53: NS 40, 80, 100
Model 111.11/16: NS 40, 50, 63 Model 213.40: NS 63, 80
Model 111.12: NS 40, 50, 63, 80, 100 Model 213.53: NS 50, 63
The instruments measure the pressure by means of resilient Bourdon tube pressure
elements
The measuring characteristics are in accordance with the EN 837-1 standard
3. Specications and intended use
Pressure limitation
Steady: 3/4 x full scale value
Fluctuating: 2/3 × full scale value
Short time: Full scale value
Mechanical connection
In accordance with the general technical regulations for pressure gauges (e.g. EN 837-2
"Selection and installation recommendations for pressure gauges").
When screwing gauges in, the force
required for this must not be applied through
the case, but rather through the spanner
ats (using a suitable tool) provided for this
purpose on the square shaft of standard
connections.
Pressure gauge models 1 and 213
per directive 94/9/EC (ATEX)
GB
Declarations of conformity see www.wika.com
Specications: see data sheet on www.wika.com
Subject to technical modications.
© 2011 WIKA Alexander Wiegand SE & Co. KG
II 2 GD c TX
Page view 0
1 2 3

Summary of Contents

Page 1 - Operating

WIKA Alexander Wiegand SE & Co. KGAlexander-Wiegand-Straße 3063911 Klingenberg • GermanyTel. (+49) 9372/132-0Fax (+49) 9372/132-406E-Mail info@

Page 2

Sealing in the thread Spanner atsSealing face Correct sealing of pressure gauge connections with parallel threads  must be made using suitable at

Page 3 - 5. Maintenance and cleaning

Permissible vibration load at the installation site The instruments should always be installed in locations free from vibration. If necessary, it is