3. Specications
3.3 Output signals
Switching output 1 Switching output 2 Analogue signal
PNP - 4 ... 20 mA
PNP - DC 0 ... 10 V
PNP PNP -
PNP PNP 4 ... 20 mA
PNP PNP DC 0 ... 10 V
Alternatively also available with an NPN instead of a PNP switching output.
With the IO-Link option, switching output 1 is always PNP.
Zero oset adjustment
maximum 3 % of span
Analogue signal
Current output load: ≤ 0.5 kΩ
Voltage output load: > 10 kΩ
Settling time: 3 ms
Switching output
Switching output 1 and 2 are individually adjustable
Normally-open and normally-closed function: freely adjustable
Window and hysteresis function: freely adjustable
Switching current
without IO-Link: maximum 250 mA
with IO-Link: maximum 100 mA
Switching voltage: Power supply - 1 V
Settling time: ≤ 10 ms