Wika A2G-25 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
WIKA operating instructions air2guide model A2G-25
GB
6
40202755.02 07/2012 GB/D/F/E/I
2. Safety / 3. Specications
2.2 Personnel qualication
WARNING!
Risk of injury if qualication is insucient!
Improper handling can result in considerable injury and
damage to equipment.
The activities described in these operating instructions
may only be carried out by skilled personnel who have
the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their
technical training, knowledge of measurement and control technology
and on their experience and knowledge of country-specic regulations,
current standards and directives, are capable of carrying out the work
described and independently recognising potential hazards.
Explanation of symbols
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant
European directives.
3. Specications
Accuracy
At 1,000 and 2,000 Pa: ±5 Pa + ±1.5 % of the display
At 5,000 and 7,000 Pa: ±7 Pa + ±1.5 % of the display
Scale ranges
0 ... 1,000, 0 ... 2,000, 0 ... 5,000 or 0 ... 7,000 Pa
Selectable units on the display: m³/s, m³/h, cfm, l/s, scfh, lpm, mbar,
mmWC, inchWC, kPa or Pa