6. Function test
6. Function test
A function test can only be carried out when the level sensor has been
removed.
Disconnect the cable
Connect an ohmmeter to two wires
Move the oat by hand from Min. to Max.
The displayed resistance value changes continuously depending on
the connected wire colours (Tab. 1):
black-brown (R1) blue-brown (R2) black-blue (Ri)
Resistance value incre-
ases in proportion to
the height of the oat.
Resistance value drops
from the value of the
total resistance inverse-
ly proportionally to the
height of the oat.
Indication of the total
resistance (Ri)
Table 1
The value of the resistance chain is given on the tag plate mounted at
the level transmitter.