l Linearisation curve
l Leak volume suppression
l Sensor-TAG
l Displayed value
l Display unit
l Language
The following safety-relevant data are not read out or written:
l PIN
Copy sensor data
Copy sensor data?
Basic adjustment
The reset "Basic adjustment" resets the following menu items to the
reset values (see chart):
Menu section Menu item Reset value
Basic settings Unit of measurement bar
Temperature unit °C
Zero/Min. adjustment Measuring range begin
Span/Max. adjustment Measuring range end
Density 1 kg/l
Density unit kg/l
Damping 1 s
Linearisation linear
Sensor-TAG Sensor
Display Displayed value AI-Out
Diagnostics Total sum counter 0.0000 10
00
gal
Part sum counter 0.0000 10
00
gal
The values of the following menu items are not reset with "Reset:
Menu section Menu item Reset value
Basic settings Application no reset
Position correction no reset
Display Lighting no reset
Reset
52 Differential pressure transmitter DPT10 - metal measuring diaphragm • F oundation Fieldbus
6 Adjustment with the indicating and adjustment module
37246-EN-100120